Updated 53m ago

CIQ Security Advisory: Remediation of CVE-2025-21647

7.1

6

03/03/2026

10/23/2026

Packages

ProductPackageSeverityScoreStatusFixed InLast UpdatedCIQ FIPS 9.6 Compliantkernel-5.14.0-570.60.1+8.1.el9_6_ciq.srcHIGH7.1fixedkernel-5.14.0-570.60.1+8.1.el9_6_ciq.src10/23/2026CIQ LTS 9.6kernel-5.14.0-570.60.1+5.1.el9_6_ciq.srcHIGH7.1fixedkernel-5.14.0-570.60.1+5.1.el9_6_ciq.src10/23/2026

CVSS v3 Score Breakdown

CVSS v3 Base Score7.1Attack VectorLOCALAttack ComplexityLOWPrivileges RequiredLOWUser InteractionNONEScopeUNCHANGEDConfidentiality ImpactHIGHIntegrity ImpactNONEAvailability ImpactHIGHVector String
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H

Remediationsvendor_fix

Update to the fixed package version from CIQ repositories

Distribution WHITE

Copyright (c) CIQ, Inc. VEX content is derived from Red Hat CSAF VEX documents (https://access.redhat.com/security/data/csaf/v2/vex/), (C) Red Hat, Inc., used under CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/); modified by CIQ.

Description

In the Linux kernel, the following vulnerability has been resolved: sched: sch_cake: add bounds checks to host bulk flow fairness counts Even though we fixed a logic error in the commit cited below, syzbot still managed to trigger an underflow of the per-host bulk flow counters, leading to an out of bounds memory access. To avoid any such logic errors causing out of bounds memory accesses, this commit factors out all accesses to the per-host bulk flow counters to a series of helpers that perform bounds-checking before any increments and decrements. This also has the benefit of improving readability by moving the conditional checks for the flow mode into these helpers, instead of having them spread out throughout the code (which was the cause of the original logic error). As part of this change, the flow quantum calculation is consolidated into a helper function, which means that the dithering applied to the ost load scaling is now applied both in the DRR rotation and when a sparse flow's quantum is first initiated. The only user-visible effect of this is that the maximum packet size that can be sent while a flow stays sparse will now vary with +/- one byte in some cases. This should not make a noticeable difference in practice, and thus it's not worth complicating the code to preserve the old behaviour.

Terms of Use

This content is licensed under the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by/4.0/). If you distribute this content, or a modified version of it, you must provide attribution to the original copyright holder(s) and provide a link to the original.